Find Combined Substation, Packed Substation, Prefabricated Substation on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Package Substation > Combined Substation

Combined Substation

Basic Info

Model No.:  YBT13-24

Product Description



Model NO.: YBT13-24


Structure: Protection


Form: All- packaged Type


Size: 3 Uint


Shell Material: Aluminum Alloy


Brand: Tianan


Test Equipment: IEC Standard


Trademark: Tianan


Origin: China




Type: Power


Certification: ISO9001:2000, CCC


Operation Voltage: High Voltage


Application Range: Power Plants


Shell Protection Grade: IP56


Tap Changer: Regulate The Output Voltage


Frequency: 50Hz


Specification: IEC60076-1, IEC60076-2, IEC60076-5


HS Code: 8535210000




Service condition

1. Altitude: ≤ 1000m (above sea level)

2. Ambient temperature: Max. 40C Min. -25C

Max. Monthly average temperature: ≤ 35C

Max. Yearly average temperature: ≤ 25C

3. Relative humidity: Daily average value≤ 95%, monthly average value≤ 90%

4. Max. Daily difference in temperature: 25C

5. Sunlight intensity: 0.1W/CM2 (wind speed 0.5M/S);

6. Outdoor wind speed: ≤ 35m/s;

7. Pollution grade: Grade III;

8. Rain proof grade: Grade 3;

9. The gradient on installation spot shall be not more than 3° ;

10. Ability of anti-earthquake: Horizontal acceleration of ground surface is 0.2g

Vertical acceleration of ground surface is 0.1g;

11. Installation spot: The spot should has no fire/explosion danger/serious pollution/chemical corrosion and exquisite shake.

Customer should negotiate with manufacturer if the service condition is different from above.



Items Unit Parameters
High Voltage Part Rated voltage kV 12
Rated frequency Hz 50
Rated current of main busbar A 630
1mm power frequency withstand voltage (to earth and between phases/disconnecting fracture) kV 42/48
Lightning impulse withstand voltage (to earth and between phases/disconnecting fracture) kV 75/85
Rated short time withstand current kA/s 25/2
Rated peak withstand current kA 63
Rated short time making current kA 50
Rated transfer current A 1500
Breaking current of fuse kA 31.5 40
Low Voltage Part Rated voltage V 400
Rated current of main circuit A 100-4000
Rated limiting short circuit breaking ability kA 80
Rated operating short circuit breaking ability kA 50 (65)
Rated short time withstand current kA/1s 50 (65)
Branch current, compensating capacity According to requirements of users
Transformer Rated capacity kVA 30-2000
Impedance voltage % 4 4.5
Tapping range % ±2×2.5 ±5
Connection symbol Y, yn0 D, yn11
Case Protection level of enclosure IP23
Sound level dB ≤50

Contact us if you need more details on Combined Substation. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Packed SubstationPrefabricated Substation. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Package Substation